Cooling tower water treatment · Nationwide

Cooling tower water treatment, done properly.

We look after cooling towers and evaporative condensers for facilities teams, data centres, hospitals and industry. Treatment, dosing, monitoring, cleaning and records, all to ACOP L8 and HSG274 Part 1, explained in plain English.

Call 020 3633 6064
  • GuidanceACOP L8
  • TechnicalHSG274 Part 1
  • SamplesUKAS-accredited lab
DWG CTT-01 Induced-draught towerNot to scale
Schematic of an induced-draught cooling tower showing the fan, drift eliminators, spray distribution, fill pack, pond, dosing and bleed, and the recirculating loop to the cooling load AIR OUT AIR IN AIR IN MAKE-UP BLEED DOSING LOAD WARM RETURN COOLED FLOW 01 02 03 04 05 06
  • 01Fan & drift eliminators
  • 02Spray distribution
  • 03Fill pack
  • 04Pond & strainers
  • 05Dosing & bleed control
  • 06Sample point
Every point we treat, test or cleanRev. A
The rules

Three documents your cooling tower lives by.

If you're the dutyholder for a site with wet cooling, these are the ones that matter. We work to all three, and we'll happily walk you through what they mean for your site.

HSE · L8

ACOP L8

The Approved Code of Practice for controlling Legionella in water systems. It sets out the dutyholder's responsibilities: assess the risk, have a written scheme, appoint a responsible person, monitor and keep records.

HSE · HSG274 Pt 1

HSG274 Part 1

The technical guidance for evaporative cooling systems. It covers treatment, monitoring frequencies, action levels for TVC and Legionella, and cleaning and disinfection at least twice a year.

SI 1992/2225

Notification Regulations 1992

The Notification of Cooling Towers and Evaporative Condensers Regulations 1992 require you to tell your local authority, in writing, about wet cooling towers and evaporative condensers on your premises.

What treatment controls

Four ways a cooling system goes wrong.

A good programme keeps all four in balance. They're connected, so fixing one while ignoring another rarely works for long.

  • 01Inhibitor + bleed

    Scale

    Hardness salts concentrate as water evaporates and coat the hottest surfaces, cutting efficiency and sheltering bacteria.

  • 02Inhibitor

    Corrosion

    Pipework, heat exchangers and casings slowly eaten away. Corrosion products also feed bacterial growth.

  • 03Dispersant + cleaning

    Fouling

    Dust, pollen and debris pulled in from the air settle in the pond and fill, soaking up biocide.

  • 04Biocides

    Microbiology

    General bacteria, biofilm and Legionella. Kept down with a biocide regime and checked by dip slides and lab samples.

Sectors

Built for sites where cooling can't fail.

Different buildings, different pressures. We plan the work around how your site actually runs. All sectors

  • Data centres

    Uptime matters more than anything, so treatment, cleaning and sampling are planned around redundancy and change control.

  • Hospitals and healthcare

    Vulnerable people nearby means less room for error. We support your Water Safety Group with clear records and quick escalation.

  • Manufacturing and process

    Process cooling, evaporative condensers and plant that can't easily stop. We treat for the process as well as the Legionella risk.

  • Food and drink processing

    Evaporative condensers on refrigeration plant are common here. We keep them clean and treated without disrupting cold chain.

  • Commercial buildings

    Offices, retail and mixed-use buildings with rooftop towers, often near air intakes, windows and busy streets.

  • M&E contractors and FM companies

    We work as your specialist water treatment partner, on your sites, to your reporting standards.

How it works

From first call to a system that's under control.

No drawn-out onboarding. Here's what happens when you bring us in.

  1. Talk it through

    A quick call about your plant, how it's used and what's worrying you. We'll ask for any existing records.

  2. Site survey

    An engineer looks at the system, the dosing kit and the log book, and checks your risk assessment is current.

  3. Programme and quote

    We set out the treatment, visit schedule and monitoring we recommend, with a clear, itemised price.

  4. Set up

    Dosing commissioned, chemicals delivered, log book organised, and a clean and disinfection booked if it's due.

  5. Routine visits

    Testing, sampling, adjustments and a short report every time. If something's off, you'll hear from us straight away.

Working with us

What you can count on.

We're not going to promise you the moon. What we will do is turn up when we say, do the job properly, and tell you plainly what we've found.

If you've ever had a treatment report that was just a page of numbers with no explanation, you'll notice the difference.

  • Results explained, not just emailed

    Every visit report says what we tested, what it means and what happens next.

  • Lab samples to a UKAS-accredited lab

    Legionella samples are analysed by an accredited laboratory, with certificates for your file.

  • Log book kept current

    We update your records on every visit, so you're always ready for an inspection.

  • One team for the whole system

    Treatment, dosing, cleaning, risk assessments and records, without juggling contractors.

  • Straight answers when something's wrong

    A high count gets a phone call and a plan, not a line buried in a report.

FAQs

Quick answers

The questions we get asked most. There are more on our FAQs page

Which regulations apply to cooling towers?

The Health and Safety at Work etc. Act 1974 and COSHH set the general duties. ACOP L8 explains how to control Legionella, and HSG274 Part 1 gives the technical guidance for evaporative cooling systems. The Notification of Cooling Towers and Evaporative Condensers Regulations 1992 require you to notify the local authority of wet cooling towers and evaporative condensers on your site.

Do I need to notify the local authority about my cooling tower?

Yes, if you have a wet cooling tower or evaporative condenser, you need to notify the local authority in writing under the 1992 Notification Regulations, and tell them if a unit is taken out of use for good. Your council will have a form for it.

How often should a cooling tower be cleaned?

HSG274 Part 1 says cooling towers should be cleaned and disinfected at least twice a year. Your risk assessment may call for more frequent cleaning.

How often should we test for Legionella?

At least quarterly for cooling systems, plus more often in certain situations, such as at commissioning or after a positive result. Dip slides for general bacteria should be done at least weekly.

Coverage

West London roots, towers looked after up and down the country.

We're based in Chiswick, West London, and most of our work is in London and the surrounding counties. We also look after sites across the rest of the UK, so if you manage plant in several regions, one contractor can cover the lot.

  • Central London
  • West London
  • City & Docklands
  • Surrey
  • Berkshire
  • Hertfordshire
  • Buckinghamshire
  • Kent
  • Essex
  • Middlesex
  • Slough & the M4 corridor
  • Nationwide

Talk to an engineer

Office
The Lightbox G16, 111 Power Road
Chiswick, London W4 5PY
Coverage
Nationwide, specialising in London & the Home Counties

Need a treatment contractor who explains things properly?

Tell us about your system and we'll come back with a clear, itemised quote. No hard sell, just a straight answer on what your site needs.

Call 020 3633 6064